There is a growing demand within North American school districts for their schools’ buildings to perform more efficiently within shrinking budgets, while simultaneously accommodating the introduction of new technologies into the classroom and operating for 50-70 years in an ever-changing environment.
As markets continue to adopt evolving standards and building codes that demand lower energy consumption, new solutions will keep gaining traction in school design.
The United States Environmental Protection Agency (EPA) defines a “High Performance School” as “energy and resource efficient.” At Price, we combine our years of occupant comfort design experience with sustainable HVAC technology to assist in achieving High Performance School design goals, reducing operating costs, maintenance and energy usage while improving the learning environment.
Displacement Ventilation (DV) is an energy efficient method of air delivery that supplies air directly into the occupied portion of the space at low air speeds. DV improves air quality and occupant satisfaction due to the manner in which the air distributes throughout the space (see Figure 1). Displacement Chilled Beams (DCB) allow engineers to combine the benefits of both chilled beam and displacement technologies into a unified system (see Figure 2).
These systems benefit school systems in particular due to their unique design and operation requirements.
Indoor environmental quality (IAQ) has been proven by several independent studies to have a major impact on health, performance and attendance of students and teachers. Displacement ventilation has shown significant improvements of the air quality in classrooms on a number of studies conducted. 5,6,7,8
The images below (Figures 4a and 4b) shows provides an illustration of what happens when contaminants, such as exhaled particles, enter the space. In a mixing space the particles released in a sneeze would be mixed throughout the space. In a displacement system the particles are pushed upward, and out of the breathing zone.
To learn more about how DV and DCB systems can be leveraged for High Performance Schools in your region, please review our High Performance Schools brochure or contact schools@priceindustries.com.
1. Arent, J., Eley, C., & Meister, B. (2006). Displacement Ventilation in Action: Performance Monitoring of Demonstration Classrooms. ACEE Summer Study on Energy Efficiency in Buildings.
2. Smedje, G., & Norback, D. (2000). New Ventilation Systems at Select Schools in Sweden - Effects on Asthma and Exposure.
3. ASHRAE. (2013). ANSI/ASHRAE Standard 62.1-2013: Ventilation for Acceptable Indoor Air Quality.
4. Jung, A. and Zeller, M. (2005). Analysis and Testing of Methods to Deter-mine Indoor Air Quality and Air Change Effectiveness. Original technical paper from Rheinisch-Westfälische Technical University of Aachen, Germany, 1994
5. ASHRAE. (2013). ANSI/ASHRAE Standard 62.1-2013: Ventilation for Acceptable Indoor Air Quality. ASHRAE.
6. Arent, J., Eley, C., & Meister, B. (2006). Displacement Ventilation in Action: Performance Monitoring of Demonstration Classrooms. ACEE Summer Study on Energy Efficiency in Buildings.
7. Smedje, G., & Norback, D. (2000). New Ventilation Systems at Select Schools in Sweden - Effects on Asthma and Exposure.
8. Jung, A., and M. Zeller, 2005. Analysis and Testing of Methods to Determine Indoor Air Quality and Air Change Effectiveness. Original technical paper from Rheinisch-Westfälische Technical University of Aachen, Germany, 1994.