title: "Case Study: Kansas City International Airport"
description: A CFD analysis was used at the Kansas City International Airport to optimize how the HVAC system interacts with the indoor environment.
image: https://blog.priceindustries.com/hubfs/KCI%20Blog%201.jpg
---

![PriceTraining_Logo_RGB-1](https://blog.priceindustries.com/hs-fs/hubfs/PriceTraining_Logo_RGB-1.png?width=303&height=58&name=PriceTraining_Logo_RGB-1.png)

 

[![Price Industries](https://blog.priceindustries.com/hubfs/Priceindustries-March-2018/Images/Price_Logo_Blue.svg)](https://www.priceindustries.com/) The Science of ComfortTM

## The Science of Comfort

Your Premier Source for All Things HVAC

# Case Study: Kansas City International Airport

Posted by [Sarah Lund](https://blog.priceindustries.com/author/sarah-lund) on August 5, 2025 at 9:00 AM

- [Tweet](https://twitter.com/share)

## CFD Model Optimizes Air Distribution in New Terminal

In February 2023, the new 40-gate terminal at Kansas City International Airport opened for commercial air service – a little more than 50 years after the original three-terminal airport began serving the area surrounding Kansas City, MO. At just over 1 million sq. ft. and with a budget of $1.5 billion, the new terminal is the largest single infrastructure project in the city’s history.

| ![Exterior view of the Kansas City International Airport](https://blog.priceindustries.com/hs-fs/hubfs/KCI%20Blog%201.jpg?width=1366&height=804&name=KCI%20Blog%201.jpg) |
| --- |
| The new 40-gate terminal opened for commercial air service in February 2023 |

The new, modern building features a large check-in hall, expanded open hold rooms and a finely tuned facade design that maximizes daylighting without sacrificing thermal comfort. The hold room and departures areas are conditioned with an overhead mixing system composed of long- and short-throw diffusers hidden up high behind architectural elements, as well as with floor grilles along the perimeter.

| ![Air travelers gathered in the airport check-in hall](https://blog.priceindustries.com/hs-fs/hubfs/KCI%20Blog%202.jpg?width=1366&height=910&name=KCI%20Blog%202.jpg) |
| --- |
| The new, modern building features a large check-in hall that maximizes daylighting |

The main design challenge of this project was balancing daylighting with solar heat gain in the departures area since it has a full-height wraparound glass facade and skylights. It was determined that the diffusers initially specified – selected from the manufacturer that was basis of design for the project – were not ideal for the space. The project team’s concerns centered around not only whether the diffusers could create and maintain occupant comfort but also whether the air jetting from the nozzles would cause a “wind chime” effect with the art pieces hanging from the ceiling. The art installations were, after all, meant to be seen, not heard.

| ![Air travelers in airport terminal](https://blog.priceindustries.com/hs-fs/hubfs/KCI%20Blog%203.jpg?width=1366&height=915&name=KCI%20Blog%203.jpg) |
| --- |
| A major design challenge was balancing daylighting with solar heat gain from the full-height wraparound glass facade and skylights |

The team at [Jorban-Riscoe](https://bit.ly/4fiRY0w) immediately thought of how the correct diffusers could be selected with the help of a [computational fluid dynamics (CFD)](https://blog.priceindustries.com/tag/cfd) analysis, which would virtually demonstrate how the HVAC system would interact with the indoor environment. [Predict, Price’s CFD modeling service](https://bit.ly/477tmFS), was used to ensure the supply air would be delivered into the occupied zone from a high sidewall location without excessive draft.

While working on this project, the Predict team spent much of its effort on a CFD model of the second-level departures area to refine diffuser sizing and placement. The CFD model showed that even though set-point temperatures were met, extra capacity was needed to offset the effect of the solar load. This was achieved with a combination of slightly more supply air volume and a lower supply air temperature, as well as with adjustments to how the drum louver diffusers were directed into the space, to optimize mixing performance.

| ![Air travelers on escalator](https://blog.priceindustries.com/hs-fs/hubfs/KCI%20Blog%204.jpg?width=1366&height=872&name=KCI%20Blog%204.jpg) |
| --- |
| Much of the CFD team’s effort was spent on a CFD model of the second-level departures area to refine diffuser sizing and placement |

The CFD results showed that reasonable adjustments to the HVAC design could yield good thermal comfort under worst-case, design-day conditions. Air travelers will no doubt enjoy both the stunning architecture and the comfortable indoor environment of the new terminal – one that Kansas City can be proud to show off to its visitors.

To learn more about how your next project can benefit from a CFD analysis, visit the [Predict website](https://bit.ly/3UtGCgJ) or contact the Predict team at [info@PredictCFD.com](mailto:info@PredictCFD.com).

[![Predict by Price](https://no-cache.hubspot.com/cta/default/4024064/8320cdda-6d65-47a3-b099-26bda0fdb4b9.png)](https://cta-redirect.hubspot.com/cta/redirect/4024064/8320cdda-6d65-47a3-b099-26bda0fdb4b9)

 Topics: [Diffusers](https://blog.priceindustries.com/tag/diffusers), [Mock-Up](https://blog.priceindustries.com/tag/mock-up), [Thermal Comfort](https://blog.priceindustries.com/tag/thermal-comfort), [HVAC](https://blog.priceindustries.com/tag/hvac), [Engineering](https://blog.priceindustries.com/tag/engineering), [Design Engineering](https://blog.priceindustries.com/tag/design-engineering), [CFD](https://blog.priceindustries.com/tag/cfd)

## At Price, when we say “the sky is the limit,” we actually mean it.

Our customers have come to count on a consistent and ever-increasing stream of new products and enhancements.  Price has a large team of experienced and talented engineers who are consistently working on breakthrough ideas.  We are not afraid to move into whole new product categories if we believe we have a contribution to make.

- Research & Innovation
- Technical Tours
- Training Classes
- Targeted Discussions
- Mock-up Testing
- Custom Solutions & Specials
- Custom Finishes
- Computational Fluid Dynamics
- Virtual Reality

### Subscribe to Email Updates

### Recent Posts

### Posts by Topic

- [HVAC (142)](https://blog.priceindustries.com/tag/hvac)
- [Engineering (118)](https://blog.priceindustries.com/tag/engineering)
- [Design Engineering (103)](https://blog.priceindustries.com/tag/design-engineering)
- [HVAC Fundamentals (82)](https://blog.priceindustries.com/tag/hvac-fundamentals)
- [Employees (38)](https://blog.priceindustries.com/tag/employees)
- [Diffusers (32)](https://blog.priceindustries.com/tag/diffusers)
- [Thermal Comfort (31)](https://blog.priceindustries.com/tag/thermal-comfort)
- [GRD (27)](https://blog.priceindustries.com/tag/grd)
- [Terminals (26)](https://blog.priceindustries.com/tag/terminals)
- [Tech Tip (25)](https://blog.priceindustries.com/tag/tech-tip)
- [Critical Environments (21)](https://blog.priceindustries.com/tag/critical-environments)
- [People of Price (19)](https://blog.priceindustries.com/tag/people-of-price)
- [Beams (17)](https://blog.priceindustries.com/tag/beams)
- [Fan Coils (17)](https://blog.priceindustries.com/tag/fan-coils)
- [Customer Service (16)](https://blog.priceindustries.com/tag/customer-service)
- [Displacement (15)](https://blog.priceindustries.com/tag/displacement)
- [Architecture (14)](https://blog.priceindustries.com/tag/architecture)
- [Noise Control (14)](https://blog.priceindustries.com/tag/noise-control)
- [13 Tenets (13)](https://blog.priceindustries.com/tag/13-tenets)
- [CFD (13)](https://blog.priceindustries.com/tag/cfd)
- [Filtration (13)](https://blog.priceindustries.com/tag/filtration)
- [Pressure Drop (13)](https://blog.priceindustries.com/tag/pressure-drop)
- [System Efficiency (13)](https://blog.priceindustries.com/tag/system-efficiency)
- [Training (12)](https://blog.priceindustries.com/tag/training)
- [Controls (11)](https://blog.priceindustries.com/tag/controls)
- [Grilles (11)](https://blog.priceindustries.com/tag/grilles)
- [Contractors (9)](https://blog.priceindustries.com/tag/contractors)
- [Engineering Update (9)](https://blog.priceindustries.com/tag/engineering-update)
- [Static Pressure (9)](https://blog.priceindustries.com/tag/static-pressure)
- [Underfloor (9)](https://blog.priceindustries.com/tag/underfloor)
- [ASHRAE 62 (7)](https://blog.priceindustries.com/tag/ashrae-62)
- [Acoustics (7)](https://blog.priceindustries.com/tag/acoustics)
- [Mock-Up (7)](https://blog.priceindustries.com/tag/mock-up)
- [ASHRAE 170 (6)](https://blog.priceindustries.com/tag/ashrae-170)
- [Heat Transfer (6)](https://blog.priceindustries.com/tag/heat-transfer)
- [Psychrometrics (6)](https://blog.priceindustries.com/tag/psychrometrics)
- [Tours (6)](https://blog.priceindustries.com/tag/tours)
- [Acoustic Panels (5)](https://blog.priceindustries.com/tag/acoustic-panels)
- [Giving (5)](https://blog.priceindustries.com/tag/giving)
- [HVAC Silencers (5)](https://blog.priceindustries.com/tag/hvac-silencers)
- [Philanthropy (5)](https://blog.priceindustries.com/tag/philanthropy)
- [ASHRAE (4)](https://blog.priceindustries.com/tag/ashrae)
- [Condensate (4)](https://blog.priceindustries.com/tag/condensate)
- [Handbook (4)](https://blog.priceindustries.com/tag/handbook)
- [Lighting (4)](https://blog.priceindustries.com/tag/lighting)
- [Noise Solution (4)](https://blog.priceindustries.com/tag/noise-solution)
- [Price Technical Center (4)](https://blog.priceindustries.com/tag/price-technical-center)
- [Cooling Coil (3)](https://blog.priceindustries.com/tag/cooling-coil)
- [Duct Noise Reduction (3)](https://blog.priceindustries.com/tag/duct-noise-reduction)
- [Events (3)](https://blog.priceindustries.com/tag/events)
- [Induction (3)](https://blog.priceindustries.com/tag/induction)
- [LEED for Schools (3)](https://blog.priceindustries.com/tag/leed-for-schools)
- [ASHRAE 70 (2)](https://blog.priceindustries.com/tag/ashrae-70)
- [Acoustic Louvers (2)](https://blog.priceindustries.com/tag/acoustic-louvers)
- [Background Noise (2)](https://blog.priceindustries.com/tag/background-noise)
- [Catalog (2)](https://blog.priceindustries.com/tag/catalog)
- [Inlet Conditions (2)](https://blog.priceindustries.com/tag/inlet-conditions)
- [Inlet Effect (2)](https://blog.priceindustries.com/tag/inlet-effect)
- [Low Temperature (2)](https://blog.priceindustries.com/tag/low-temperature)
- [Noise Criteria (2)](https://blog.priceindustries.com/tag/noise-criteria)
- [Outlet Conditions (2)](https://blog.priceindustries.com/tag/outlet-conditions)
- [Price International (2)](https://blog.priceindustries.com/tag/price-international)
- [Reverberation Time (2)](https://blog.priceindustries.com/tag/reverberation-time)
- [Software (2)](https://blog.priceindustries.com/tag/software)
- [Sound Absorption (2)](https://blog.priceindustries.com/tag/sound-absorption)
- [Sound Masking (2)](https://blog.priceindustries.com/tag/sound-masking)
- [Speech Privacy (2)](https://blog.priceindustries.com/tag/speech-privacy)
- [Velocity Profile (2)](https://blog.priceindustries.com/tag/velocity-profile)
- [AROW (1)](https://blog.priceindustries.com/tag/arow)
- [Air Transfer Silencers (1)](https://blog.priceindustries.com/tag/air-transfer-silencers)
- [Ceiling Attenuation Class (1)](https://blog.priceindustries.com/tag/ceiling-attenuation-class)
- [LEED credits (1)](https://blog.priceindustries.com/tag/leed-credits)
- [LEED for Healthcare (1)](https://blog.priceindustries.com/tag/leed-for-healthcare)
- [Public Transit (1)](https://blog.priceindustries.com/tag/public-transit)
- [Sound Transmission Class (1)](https://blog.priceindustries.com/tag/sound-transmission-class)
- [Supply Chain (1)](https://blog.priceindustries.com/tag/supply-chain)
- [System Effect (1)](https://blog.priceindustries.com/tag/system-effect)
- [Transportation (1)](https://blog.priceindustries.com/tag/transportation)

see all

Follow us:

- [![Follow us on Twitter](https://blog.priceindustries.com/hubfs/Priceindustries-March-2018/Images/Twitter-icon.svg)](https://twitter.com/PriceHVAC)
- [![Subscribe to us on YouTube](https://blog.priceindustries.com/hubfs/Priceindustries-March-2018/Images/YouTube-icon.svg)](https://www.youtube.com/user/PriceHVAC)
- [![Follow us on LinkedIn](https://blog.priceindustries.com/hubfs/Priceindustries-March-2018/Images/LinkedIn-icon.svg)](https://www.linkedin.com/company/price-industries)

Have a question? [Contact Product Support](https://www.priceindustries.com/contact/product-support)

### Price Industries - Who We Are

The founding principles of Price have never changed – business integrity, first-class service, innovation and a commitment to people. Our dependable quality, reliable delivery, and knowledgeable follow-up service have made Price a market leader in supplying air distribution, critical controls, and noise control products. After more than 60 years, Price remains a privately held family company with a deep heritage and commitment to innovation and service. Our long-standing vision, traditional values, and the Price way of doing business are the cornerstones of our leadership position in the non-residential air distribution industry.

- - [Privacy Policy](https://www.priceindustries.com/legal/privacypolicy)
    - [Engineering E-Update](https://www.priceindustries.com/signup/newsletter)
- - [Contact Information](https://www.priceindustries.com/contact/reps-dealers?territory=International)
    - [Career Opportunities](https://www.priceindustries.com/corporate/careers)
    - [Our Services](https://www.priceindustries.com/services)

![Price Industries](https://blog.priceindustries.com/hubfs/Priceindustries-March-2018/Images/PriceLogo-footer.png) © 2018 Price Industries. All Rights Reserved. 2975 Shawnee Ridge Court - Suwanee, Georgia 30024 - (770) 623-8050.

- **Current Market:**
- [Canada](https://www.priceindustries.com/?SwitchMarket=Canada)
- [United States](https://www.priceindustries.com/?SwitchMarket=United%20States)
- [International](https://www.priceindustries.com/?SwitchMarket=International)